Bigger spaces, bigger systems
A warehouse fire can grow fast. High racking, packaging, pallets and stock give it plenty of fuel, and a big open floor gives it room. That is why industrial buildings tend to carry the heavier fire systems: hydrants and boosters for the fire brigade, hose reels for staff, and often sprinklers and fire water tanks.
Those systems are also the ones most often let down by daily operations: a pallet in front of a hose reel, a forklift strike on a hydrant, or a sprinkler valve left closed after maintenance.
What we look after
We service each item on your Form 1 schedule on the frequency set by MBS 002 (version 3, May 2023), South Australia’s maintenance instrument.
| System | How often it is serviced |
|---|---|
| Hydrants and boosters | Monthly to 5-yearly |
| Fire hose reels | 6-monthly and yearly |
| Sprinklers, tanks and pumps | On the AS 1851-2012 schedule for your system |
| Portable extinguishers | Every 6 months, plus yearly and 5-yearly |
| Detection and alarm | Monthly to 5-yearly |
| Exit and emergency lighting | 6-monthly and yearly, plus monthly checks |
| Hinged fire doors | Every 6 months |
Testing firefighting equipment connected to mains water needs CBS test and inspect registration (General, Hydrant and hose reel, or Trainee). Annual and longer tests, other than on hose reels, need plumbing registration. We hold a CBS PGE fire plumbing licence and are FPAS accredited (Fire Protection Accreditation Scheme). Ask us which registrations apply to the tests on your site.
Keeping equipment clear
At every visit we check that extinguishers, hose reels, hydrants, the booster, exit lights and exits can be reached and seen. In a busy warehouse, those are the first things to disappear behind stock. Each obstruction goes in the report with its location, so the warehouse manager can clear it the same day.
We also flag damage that operations cause: forklift strikes on hose reel cabinets and hydrant pipework, crushed extinguisher brackets, and exit lights knocked out of line.
The right extinguisher for the hazard
Industrial sites often need several types: powder for general areas, CO2 near switchboards and electrical plant, and specialist types for particular processes. We check that each extinguisher matches the hazard beside it and that new hazards, such as a new battery-charging area for forklifts, have the right cover. See fire extinguishers and our guide to extinguisher types and colours.
Test and tag every 6 months in manufacturing
SafeWork SA sets 6-monthly testing for electrical equipment used in manufacturing, and at least every 12 months in other hostile environments. The WHS regulations that apply are 150 and 163 to 165, and AS/NZS 3760:2022 is the guidance testers follow. We test and tag single-phase and 3-phase equipment, test safety switches (RCDs), and keep one register for the site. See test and tag.
We are qualified and licensed for electrical test and tag.
Form 3 and records
Most industrial buildings must lodge a Form 3 with council within 60 business days after the end of each calendar year. Smaller Class 3 to 9b buildings (a rise of 2 storeys or less and 500 m² or less) are exempt from lodging unless a section 157 notice or a performance solution applies, but must still maintain their essential safety provisions. We supply the maintenance records and sign the contractor section, but the Form 3 stays the owner’s obligation. See essential safety provisions and Form 3.
Emergency plans for industrial sites
Every workplace needs an emergency plan under WHS regulation 43. In an industrial building it needs to cover big floor areas where the alarm may be hard to hear, forklift traffic, after-hours shifts, any dangerous goods, and where the fire brigade connects to the booster. See emergency management plans.
How we work with industrial sites
We work around shifts and loading schedules, isolate only what we need to, and restore systems before we leave. Each visit ends with a report by system and location, ready for your safety file and the owner’s Form 3.
The rules that apply
| Requirement | What it means | Standard | SA source |
|---|---|---|---|
| Fire hydrants and boosters | Monthly to 5-yearly | AS 1851-2012 | MBS 002 v3 (SA) |
| Fire hose reels | 6-monthly and yearly | AS 1851-2012 | MBS 002 v3 (SA) |
| Portable fire extinguishers | Every 6 months, plus yearly and 5-yearly | AS 1851-2012 | MBS 002 v3 (SA) |
| Testing equipment connected to mains water | CBS test and inspect registration. Annual and longer tests (other than hose reels) need plumbing registration | Plumbing licensing (SA) | CBS |
| Electrical equipment in manufacturing | Every 6 months | WHS Regulations 150 and 163 to 165, with AS/NZS 3760:2022 as guidance | SafeWork SA |
| Workplace emergency plan | Prepared, maintained and implemented | WHS Regulations 2012 (SA), regulation 43 | SafeWork SA |
What customers say about our industrial and warehouses work
VD Fire Safety and Electrical Company is highly recommended for its compliance services. The staff expertly installed industrial-grade extinguishers and blankets, as well as conducted installation and testing of equipment. They also ensured proper inspection and testing of exit/emergency lights and smoke alarms.