Fire safety in an office is mostly about records
Offices are rarely high-risk buildings, and that is the problem. Nothing happens for years, so a dead exit light, an extinguisher that missed its service or a fire door wedged open for summer can go unnoticed until an audit or an emergency. In South Australia, the paperwork matters as much as the equipment, because the building owner has to certify each year that the essential safety provisions were maintained.
We keep both in order: the equipment serviced on schedule, and a record for every service that the owner can rely on.
What we look after in an office building
Your building’s Form 1 schedule of essential safety provisions (ESPs) lists what it has. We service each item on the schedule set by South Australia’s maintenance instrument, MBS 002 (version 3, May 2023).
| System | How often it is serviced |
|---|---|
| Portable extinguishers and fire blankets | Every 6 months. Extinguishers also yearly and 5-yearly |
| Exit and emergency lighting | 6-monthly and yearly, plus monthly checks |
| Fire detection and alarm | Monthly to 5-yearly |
| Hinged fire doors | Every 6 months |
| Fire hose reels | 6-monthly and yearly |
| Hydrants and boosters | Monthly to 5-yearly |
Testing firefighting equipment connected to mains water needs CBS test and inspect registration. We hold a CBS PGE fire plumbing licence and are FPAS accredited (Fire Protection Accreditation Scheme). Ask us which registrations apply to the tests on your building.
Form 3 for commercial buildings
The owner lodges a Form 3 with council within 60 business days after the end of each calendar year, certifying that the ESPs were maintained. Class 3 to 9b buildings with a rise of 2 storeys or less and 500 m² or less are exempt from lodging unless a section 157 notice or a performance solution applies, but they must still maintain their ESPs.
Councils cite $750 expiations for not lodging or not maintaining, and up to $10,000 if prosecuted. We supply the maintenance records behind the Form 3 and sign the contractor section for the work we did. The certificate stays the owner’s obligation. See essential safety provisions and Form 3.
Landlords, tenants and shared buildings
In a multi-tenant building, the owner looks after the base-building systems: alarms, exit lighting, hydrants, fire doors and common-area extinguishers. Each tenant is a separate workplace with its own emergency plan, staff and often its own equipment. Problems start when nobody is sure whose job a particular item is.
We can service the whole building on one visit and report separately to each party, so the owner has the Form 3 records and each tenant has the records for its own equipment. If a tenancy fit-out has moved extinguishers or blocked an exit light, we tell both sides.
Emergency plans and wardens
Every office needs an emergency plan under WHS regulation 43. It must cover evacuation, notifying emergency services, medical assistance, communication, how often the procedures are tested and how workers are trained. In a shared building, each tenant’s plan needs to agree with the building’s alarm, exits and assembly area.
We can help with emergency management plans and evacuation diagrams.
Test and tag for offices
Offices have computers, chargers, kitchen appliances, heaters and power boards, many of them brought in by staff. We can test and tag them on the same visit as your fire servicing, from $3.50 + GST per item, and keep one register for the whole office.
How we work with offices
We book visits around business hours, warn staff and building management before alarm or bell tests, and keep the noisy tests short. Each visit ends with a report by floor and by system, ready to file. Tell us when the building is quietest and we’ll work out a time.
The rules that apply
| Requirement | What it means | Standard | SA source |
|---|---|---|---|
| Annual Form 3 (ESP maintenance certificate) | Within 60 business days after the end of each calendar year | Planning, Development and Infrastructure (General) Regulations 2017 | PlanSA Form 3 |
| Portable extinguishers and fire blankets | Every 6 months (extinguishers also yearly and 5-yearly) | AS 1851-2012 | MBS 002 v3 (SA) |
| Emergency and exit lighting | 6-monthly and yearly, plus monthly checks | AS/NZS 2293.2 | MBS 002 v3 (SA) |
| Fire detection and alarm systems | Monthly to 5-yearly | AS 1851-2012 | MBS 002 v3 (SA) |
| Hinged fire doors | Every 6 months | AS 1851-2012 | MBS 002 v3 (SA) |
| Workplace emergency plan | Prepared, maintained and implemented | WHS Regulations 2012 (SA), regulation 43 | SafeWork SA |