Every South Australian workplace must have an emergency plan with evacuation procedures under WHS regulation 43, and a displayed evacuation diagram is the usual way to show people the way out. AS 3745 sets out what a good diagram contains and is widely treated as best practice, but no SA law we have found makes AS 3745 diagrams mandatory.
VD Fire & Electrical prepares evacuation diagrams and emergency plans for businesses and properties across Adelaide.
What an evacuation diagram is
An evacuation diagram is a simplified floor plan displayed on the wall that shows people where they are and how to get out. It marks the exits, evacuation routes, assembly area and the location of key emergency equipment such as extinguishers and alarm call points. Someone who has never been in your building before should be able to work out where to go in seconds.
The diagram is one part of a wider emergency plan. The diagram tells people where to go. The plan covers who does what, how the emergency is communicated and how people are trained.
Are evacuation diagrams mandatory in SA?
The legal duty in South Australia is the emergency plan, not the diagram itself.
- Work health and safety. Regulation 43 of the Work Health and Safety Regulations 2012 (SA) requires every workplace to have an emergency plan. SafeWork SA’s Code of Practice on managing the work environment and facilities says the plan must include emergency procedures (including evacuation), testing of those procedures, and information, training and instruction for workers. The plan must be kept up to date so it stays effective. The code also says procedures should cover a site plan showing fire protection equipment, emergency exits and assembly points, and that evacuation procedures should be displayed somewhere prominent.
- AS 3745. AS 3745, Planning for emergencies in facilities, sets out what an evacuation diagram should contain and how it should be displayed. SafeWork SA’s code points to it for further guidance. It is best practice, but no SA law we have found mandates it.
- Sector rules. Some buildings and services have their own requirements. Childcare centres must rehearse their emergency and evacuation procedures every 3 months (Education Standards Board). For disability accommodation, see our SDA fire safety guide.
- Contracts and insurance. Leases, insurers and head contractors often ask for diagrams drawn to AS 3745.
Because requirements vary, the best first step is to check what your building, sector and contracts require. Your building certifier can advise on any conditions attached to the building’s approvals.
When evacuation diagrams in Adelaide need updating
A diagram is only useful if it matches the building as it stands today. Update it whenever the layout changes, exits are moved or blocked, tenancies change, or fire equipment is added or relocated.
The plan itself must be tested at the frequency the plan sets, usually through evacuation exercises. WHS regulation 43 requires the plan to cover testing but doesn’t fix a number. SafeWork SA’s code suggests evacuation practice drills at least every 12 months, so set a frequency that suits your site and record each exercise. Our fire drills guide covers how to run one.
What goes into evacuation diagrams in Adelaide
AS 3745 sets out what a diagram should show and how it is laid out, which is why a generic template often doesn’t meet it. At the least, a reader should be able to see where they are, the way out from that spot, the assembly area and the fire equipment nearby. If you’d like diagrams prepared for your building, we can arrange a site visit and a quote.
How fire alarm block plans differ from evacuation diagrams
A fire alarm block plan is a different drawing with a different audience. Under MFS Policy 037, block plans are kept at the fire alarm panel for fire service use and show each floor, the location of every detector and manual call point, and how to reach them, so attending firefighters can quickly find where an alarm has been triggered. If your building has a fire alarm system, you’ll usually have a block plan beside the panel. It doesn’t replace the evacuation diagrams that occupants see on the walls.
Whichever drawings apply to your building, keep copies of current diagrams, plan review dates and exercise records. Gaps usually surface during an audit, an insurance review or a SafeWork SA visit. None of this is difficult to fix, but it’s far easier before someone asks.
Working out what your building needs is mostly a matter of checking your emergency plan, comparing what’s on the wall to AS 3745 and fixing the gaps. After that, it’s keeping diagrams current as the building changes. For help with either step, call VD Fire & Electrical on 08 8151 1040. For the standard itself, see our guide to AS 3745.