Planning for the people who can’t evacuate themselves
Babies and toddlers can’t walk out of a building on their own, and young children follow adults, not signs. Fire safety in childcare and schools is about getting a group of small people out quickly and calmly, with every child accounted for. That depends on working equipment, a plan that suits the building, and staff who have practised it.
Evacuation rehearsals every 3 months
ACECQA’s guidance under the Education and Care Services National Regulations says each approved service must rehearse its emergency and evacuation procedures every 3 months, and document each rehearsal. South Australia’s regulator, the Education Standards Board, expects services to rehearse one invacuation and one evacuation procedure every 3 months, and to review the potential emergencies risk assessment every 12 months, or sooner if something changes that could affect the safe evacuation of children.
We can help services get ready for those rehearsals:
- evacuation diagrams that match the building and the rooms children use today
- a check that exits, exit signs, alarms and fire doors work before the rehearsal
- updates to the emergency plan when rooms, ages or numbers change
Keep a record of each rehearsal: the date, the scenario, the time to evacuate, who took part and what to improve. Ask us about being on site for one.
Schools
Schools are workplaces, so every school needs an emergency plan under WHS regulation 43. The plan must cover evacuation, notifying emergency services, medical assistance, communication, training, and how often the procedures are tested. Large campuses with several buildings, ovals and gyms need assembly areas, warden areas and alarm coverage planned across the whole site.
Equipment we look after
We service each item on the frequency set by MBS 002 (version 3, May 2023), South Australia’s maintenance instrument.
| System | How often it is serviced |
|---|---|
| Portable extinguishers | Every 6 months, plus yearly and 5-yearly |
| Fire blankets | Every 6 months |
| Exit and emergency lighting | 6-monthly and yearly, plus monthly checks |
| Detection and alarm | Monthly to 5-yearly |
| Hinged fire doors | Every 6 months |
If your building lodges a Form 3, we supply the maintenance records and sign the contractor section. The owner lodges it with council within 60 business days after the end of each calendar year. See essential safety provisions and Form 3.
Kitchens, laundries and sleep rooms
Childcare centres concentrate their fire risk in a few rooms: the kitchen, the laundry with its dryer, and the storeroom full of art supplies and nappies. Sleep rooms need particular thought, because the children in them are the slowest to move. We check that extinguishers and blankets are close to the kitchen and laundry, that exits from sleep rooms are clear, and that cots and evacuation equipment don’t block the route out.
Staff training
Educators are the wardens in a childcare centre. Every staff member should know the alarm, the routes, the assembly area, how to take the attendance record with them and how to move babies who can’t walk. We write the emergency plan and evacuation diagrams that educators train on.
Test and tag
Centres and schools have kitchens, laundries, computers, heaters and art equipment. We can test and tag them on the same visit as the fire servicing, with one register for the service.
How we work with services
We plan visits around sessions, sleep times and school hours, tell staff before any alarm is tested and keep noisy tests short, so children aren’t frightened by a false drill. Each visit ends with a report the director can file for assessment and rating visits.
The rules that apply
| Requirement | What it means | Standard | SA source |
|---|---|---|---|
| Childcare emergency and evacuation rehearsals | Every 3 months | Education and Care Services National Regulations | ACECQA and Education Standards Board SA |
| Childcare potential emergencies risk assessment | Every 12 months, and when circumstances change | Education and Care Services National Regulations, regulation 97 | Education Standards Board SA |
| Workplace emergency plan | Prepared, maintained and implemented | WHS Regulations 2012 (SA), regulation 43 | SafeWork SA |
| Portable extinguishers and fire blankets | Every 6 months (extinguishers also yearly and 5-yearly) | AS 1851-2012 | MBS 002 v3 (SA) |
| Emergency and exit lighting | 6-monthly and yearly, plus monthly checks | AS/NZS 2293.2 | MBS 002 v3 (SA) |