Patients change the plan
Most of the people in a medical centre at any moment are patients, and some of them can’t leave quickly. A patient may be in a dental chair, recovering from a procedure, using a walking frame or in a wheelchair. A good fire safety set-up gives staff warning early, keeps smoke out of the escape route and gives them a plan they have practised.
What we look after
Your building’s Form 1 schedule of essential safety provisions (ESPs) lists what it has. We service each item on the schedule set by South Australia’s maintenance instrument, MBS 002 (version 3, May 2023).
| System | How often it is serviced |
|---|---|
| Detection and alarm | Monthly to 5-yearly |
| Exit and emergency lighting | 6-monthly and yearly, plus monthly checks |
| Hinged fire doors | Every 6 months |
| Portable extinguishers and fire blankets | Every 6 months. Extinguishers also yearly and 5-yearly |
| Sprinklers, where fitted | On the AS 1851-2012 schedule for your system |
Form 3 for healthcare buildings
The owner lodges a Form 3 with council within 60 business days after the end of each calendar year, certifying that the ESPs were maintained. Class 3 to 9b buildings with a rise of 2 storeys or less and 500 m² or less are exempt from lodging unless a section 157 notice or a performance solution applies, but must still maintain their ESPs. We supply the maintenance records and sign the contractor section, but the certificate stays the owner’s obligation. See essential safety provisions and Form 3.
Fire doors and smoke compartments
In larger clinics and day hospitals, fire and smoke doors let staff move patients away from a fire without leaving the building. Those doors get wedged open for trolleys and beds, and their closers and seals wear out. We inspect hinged fire doors every 6 months and report each door by location.
Oxygen, chemicals and equipment
Clinics often store medical gases, cleaning chemicals and sterilising equipment. Those change the fire risk and the extinguisher types you need. We check that extinguishers match the hazards in each room and that storage doesn’t block equipment or exits.
Emergency plans for clinics
Every practice needs an emergency plan under WHS regulation 43. It must cover evacuation, notifying emergency services, medical assistance, communication, training and how often the procedures are tested. For a clinic, the hardest part is patients who need help, so the plan should name who helps whom and what happens to a procedure in progress when the alarm sounds. AS 3745 is the best-practice standard for emergency planning, but no SA law we have found mandates it.
See emergency management plans and evacuation diagrams.
Test and tag and safety switches
Clinics have computers, kettles, heaters and chargers alongside clinical equipment. We test and tag general equipment and test safety switches (RCDs) on the same visit as the fire service.
How we work with clinics
We plan visits around consulting hours, tell reception before any alarm test and keep the waiting room undisturbed. Each visit ends with a report by system and by room, ready for your practice accreditation file and the owner’s Form 3.
The rules that apply
| Requirement | What it means | Standard | SA source |
|---|---|---|---|
| Annual Form 3 (ESP maintenance certificate) | Within 60 business days after the end of each calendar year | Planning, Development and Infrastructure (General) Regulations 2017 | PlanSA Form 3 |
| Fire detection and alarm systems | Monthly to 5-yearly | AS 1851-2012 | MBS 002 v3 (SA) |
| Emergency and exit lighting | 6-monthly and yearly, plus monthly checks | AS/NZS 2293.2 | MBS 002 v3 (SA) |
| Hinged fire doors | Every 6 months | AS 1851-2012 | MBS 002 v3 (SA) |
| Portable extinguishers and fire blankets | Every 6 months (extinguishers also yearly and 5-yearly) | AS 1851-2012 | MBS 002 v3 (SA) |
| Workplace emergency plan | Prepared, maintained and implemented | WHS Regulations 2012 (SA), regulation 43 | SafeWork SA |