Based in Enfield. Working across Adelaide and regional SA. 08 8151 1040

Essential safety provisions and Form 3 in Adelaide

We inspect, test and maintain the essential safety provisions listed on your building's Form 1, then give you the maintenance records and sign the contractor section of your Form 3. As the owner, you lodge Form 3 with council within 60 business days after the end of each calendar year, and our work is quoted per building.

Our technician at a row of fire hydrant pillars outside a commercial building, toolbox open

What essential safety provisions are

Essential safety provisions, or ESPs, are the fire and life safety systems a building relies on to protect people. They include fire extinguishers, hose reels, hydrants, sprinklers, smoke detection and alarm systems, emergency and exit lighting, fire doors and similar features. Which ones your building has, and which ones council expects you to maintain, are listed on your building’s Form 1.

In South Australia, the building owner is responsible for keeping those provisions working for the life of the building. The maintenance standard is Ministerial Building Standard MBS 002, version 3 (May 2023). It replaced SA 76 and calls up AS 1851-2012 for fire protection systems and AS/NZS 2293.2 for emergency lighting.

Form 1, Form 2 and Form 3

Form Who issues or signs it What it is
Form 1 Council or the relevant authority The schedule of essential safety provisions for the building and how each must be maintained
Form 2 The installer, on completion of each installation Confirms each provision was installed as approved. See Form 2
Form 3 The building owner, every year Confirms the provisions were maintained and tested during the calendar year

Form 1 is your starting point. If you do not have a copy, ask your council, because it tells you and your contractors exactly what must be maintained. PlanSA’s Form 3 template must be used from calendar year 2023, so older forms from the previous Development Regulations should no longer be used.

Who has to lodge a Form 3

Most commercial and multi-unit buildings with a Form 1 must lodge a Form 3 every year. Regulation 94 of the Planning, Development and Infrastructure (General) Regulations 2017 exempts:

  • Class 1b buildings
  • Class 3, 4, 5, 6, 7, 8 and 9b buildings with a rise of 2 storeys or less and a floor area of 500 m² or less

Council can still require a Form 3 from a small building if its provisions were installed as part of a performance solution, or if it has been the subject of a section 157 notice. Class 2, 9a and 9c buildings are not on the list, so apartment, health-care and residential care buildings lodge whatever their size. Class 1a houses and Class 10 structures sit outside the scheme altogether. Our guide to NCC building classes in SA explains each class.

Being exempt from lodging does not mean being exempt from maintaining. Exempt owners must still keep their essential safety provisions working and maintained. Workplaces also have separate WHS duties to keep firefighting equipment in working order.

The 60-business-day deadline

Form 3 is due within 60 business days after the end of each calendar year, under regulation 94 of the Planning, Development and Infrastructure (General) Regulations 2017. It covers the maintenance done from 1 January to 31 December. Because business days exclude weekends and public holidays, the exact date moves each year, so check it with your council.

The paperwork is the easy part. The practical risk is the maintenance gaps. If a 6-monthly service was missed in July, you cannot fix that in February. The safest approach is to have every provision on a schedule from January, so the records are complete by the time the form is due.

What happens if you don’t comply

Councils cite $750 expiations for not lodging a Form 3 or not maintaining essential safety provisions, and penalties of up to $10,000 if an owner is prosecuted. The City of Marion’s factsheet also says that, in serious cases, councils can revoke a Certificate of Occupancy where non-compliance puts occupants at risk.

Building Fire Safety Committees also play a part. A committee can issue a notice under section 157 of the Planning, Development and Infrastructure Act 2016 that requires the owner to deal with fire safety problems. A building with a section 157 notice also loses the small-building Form 3 exemption.

What we do, and what stays with you

We want this to be clear, because getting it wrong causes problems at council.

What we do:

  • Read your Form 1 and set up a maintenance schedule for every provision we look after
  • Inspect, test and service each provision at the frequency MBS 002 sets
  • Give you a written report after every visit, with defects and quotes listed separately
  • At year end, give you the maintenance records for the calendar year
  • Sign the contractor section of Form 3 for the provisions we maintained

What stays with you as the owner:

  • Lodging Form 3 with council by the deadline
  • Signing the owner’s part of the form
  • Fixing defects, or approving us or another contractor to fix them
  • Making sure provisions maintained by other contractors are also covered

If another contractor looks after part of your building, such as the sprinkler system or a monitored fire panel, their records need to be included too. We can work alongside them.

VD Fire & Electrical is FPAS accredited (Fire Protection Accreditation Scheme), a member of FPA Australia and holds a CBS PGE fire plumbing licence. We are qualified and authorised to carry out fire safety maintenance and to sign off SA council ESP Form 2 and Form 3 maintenance documentation. Lodging Form 3 with council stays with you as the owner. Send us your Form 1 and we’ll confirm which provisions on it we maintain before you sign up.

What happens across the calendar year

Form 3 covers 1 January to 31 December, so the work is planned on the calendar year.

When What we do as your contractor What you do as the owner
Before 1 January Read your Form 1 and book every service it calls for in the coming year Send us the Form 1 and tell us about any other contractors on site
Each month, where the Form 1 lists monthly checks Carry out the monthly checks, such as those for emergency lighting Keep the provisions accessible on the day
First half of the year First 6-monthly round across the provisions we maintain, with a report after each visit Approve repairs for any defects we report
Second half of the year Second 6-monthly round, the yearly services, and any 3-yearly or 5-yearly services that fall due this year Approve repairs, and check other contractors are on schedule
December Check every provision on the schedule has a record for the year and follow up open defects Have defects fixed, or a plan to fix them in place
January to the deadline Give you the yearly records pack and the signed contractor section Sign the owner’s part and lodge Form 3 with council within 60 business days after 31 December

Sixty business days is a little over 12 weeks once weekends and public holidays are taken out. The 6-monthly rounds don’t have to fall in exactly these months. What matters is that each service happens at the interval MBS 002 sets, and is recorded in the calendar year it belongs to. For strata corporations, property managers and owners with several buildings, we can put every building on the same schedule and send consolidated reports.

What the yearly records pack contains

After 31 December you get one pack for the year, covering the provisions we maintain:

  • Service records against your Form 1. A dated record for each provision on the schedule, showing each service done during the calendar year at the frequency MBS 002 sets.
  • Defects found and fixed. Each defect raised during the year and when it was fixed. Anything still open is listed with the steps being taken, because Form 3 asks you to confirm there are no outstanding defects or that they are being rectified.
  • The signed contractor section of Form 3 for the provisions we maintained.

Keep each pack. Under regulation 94, an authorised officer can ask for written proof of maintenance and testing covering up to the 2 previous calendar years, and you have 48 hours to provide it.

Which tests need a CBS registration

Testing firefighting equipment connected to mains water is restricted plumbing work in South Australia, so the person doing it needs the right registration from Consumer and Business Services (CBS):

Provision and test What CBS requires
Fire hose reels, 6-monthly and yearly tests A test and inspect registration (General, or Hydrant and hose reel)
Hydrant valves and booster assemblies, up to 6-monthly tests A test and inspect registration (General, or Hydrant and hose reel)
Sprinklers and other water-based systems, 6-monthly or more frequent tests A General test and inspect registration
Hydrants, sprinklers and other mains-connected systems, yearly and longer tests such as 3-yearly tests A plumbing worker’s registration that authorises the work, such as one restricted to fire protection work
Any of the above done by a trainee A Trainee test and inspect registration, working under the direct supervision of a registered person
Extinguishers, exit and emergency lighting, fire doors Outside these registrations, which cover equipment connected to mains water

The General and Hydrant and hose reel registrations don’t cover installation or repair, apart from hose reel parts downstream of the gate valve, and a Trainee registration covers neither. When you compare contractors, ask which registration covers each test on your Form 1.

Send us your Form 1 schedule and we’ll quote the year

Every building’s schedule is different, so we quote per building. Send us your Form 1 schedule and we’ll quote the whole calendar year of services for the provisions we maintain, with the records pack and the signed contractor section at year end.

New owner, new manager or a missed year

Many Form 3 problems start when a building changes hands or a new property manager takes over, and nobody is sure what was done last year. If that sounds familiar, start here:

  • Get the Form 1. Ask council for the building’s current schedule of essential safety provisions. Without it, nobody can say for certain what must be maintained.
  • Find last year’s records. Ask the previous owner, manager or contractor for service reports and any lodged Form 3. Council may also be able to tell you whether a Form 3 was received.
  • Check what is actually installed. Older buildings are often altered over the years. A site check against the Form 1 shows what is missing, extra or overdue.
  • Book the overdue services now. Do not wait for the next deadline. Each month without a service is a month that cannot be recorded as maintained.

We can do the site check as part of a fire safety inspection and then move straight into a maintenance schedule. If council has already contacted you, tell us when you book so we can prioritise the provisions it has raised.

Code changes from 1 May 2027

The National Construction Code 2022 applies in South Australia until 30 April 2027. NCC 2025 starts on 1 May 2027. If you are planning building work or a change of use around that date, ask your building certifier which edition will apply and what it means for your building’s Form 1 schedule. Your existing maintenance obligations continue in the meantime.

Standards and service frequency in SA

EquipmentHow oftenStandardSA source
Form 3 (ESP maintenance certificate) Every calendar year, lodged with council within 60 business days after 31 December Planning, Development and Infrastructure (General) Regulations 2017 (SA), regulation 94, and the PlanSA Form 3 template, required from calendar year 2023 PlanSA, Advisory Notice 01/22
Maintenance and testing of essential safety provisions As set for each provision, from monthly to 5-yearly MBS 002 version 3 (May 2023), calling up AS 1851-2012 and AS/NZS 2293.2 PlanSA, MBS 002 v3
Form 3 exemption Class 1b, and Class 3, 4, 5, 6, 7, 8 and 9b with a rise of 2 storeys or less and 500 m² or less, unless council requires one because of a performance solution or a s157 notice. Provisions must still be maintained Planning, Development and Infrastructure (General) Regulations 2017 (SA), regulation 94(12) and (13) legislation.sa.gov.au
Penalties $750 expiation, or up to $10,000 if prosecuted Planning, Development and Infrastructure Act 2016 (SA) City of Adelaide and City of Marion ESP factsheet

Who this is for

Certificates and reporting

Every visit ends with a written report listing each item tested, its location and result, and anything that needs attention. Building owners use it as the maintenance record behind their annual Form 3. We are qualified and authorised to carry out fire safety maintenance and sign off SA council ESP Form 2 and Form 3 maintenance documentation.

Ask us for a sample report if you want to see the format before you book.

Who does the work

  • FPAS Recognised BusinessFire Protection Accreditation Scheme
  • FPA Australia Bronze MemberFire Protection Association Australia
  • Engineers AustraliaMember of the national body for engineers
  • CBS PGE fire plumbing licenceConsumer and Business Services SA
  • Licensed for electrical test and tagAS/NZS 3760 testing

All licences and certificates are held by suitably qualified personnel, and we are fully insured.

What customers say about our essential safety provisions (form 3) work

VD Fire Safety and Electrical Company is highly recommended for its compliance services. The staff expertly installed industrial-grade extinguishers and blankets, as well as conducted installation and testing of equipment. They also ensured proper inspection and testing of exit/emergency lights and smoke alarms.

Additionally, the company provided valuable assistance in completing the ESP Certificate Form-3 and facilitated the submission process to the council.

I would highly recommend their services.

Geetmate. Google review, 5 out of 5, February 2025.

“I run a small cafe in the CBD and needed urgent fire extinguisher testing and electrical test and tag for council required ESP Form-3 in Adelaide. These guys were responsive, affordable, and gave us complete peace of mind.

Jaimil Patel. Google review, 5 out of 5, July 2025.

All reviews

Frequently asked questions

What is a Form 3 in South Australia?
Form 3 is the annual certificate a building owner gives council to confirm that the building's essential safety provisions have been maintained and tested as required. It is due within 60 business days after the end of each calendar year. PlanSA's current Form 3 template must be used from calendar year 2023.
Who is responsible for lodging the Form 3?
The building owner. The owner can use contractors to do the maintenance, and we sign the contractor section for the provisions we look after, but the obligation to lodge stays with the owner.
When is Form 3 due?
Within 60 business days after 31 December each year, for the calendar year just ended. Weekends and public holidays do not count, so the exact date moves a little each year. Check your council's ESP page for the date it is working to.
Is my building exempt from Form 3?
Class 1b buildings are exempt, and so are Class 3, 4, 5, 6, 7, 8 and 9b buildings with a rise of 2 storeys or less and a floor area of 500 m² or less. Council can still require a Form 3 if a section 157 notice or a performance solution applies. Class 2, 9a and 9c buildings have no size exemption, and Class 1a and Class 10 buildings sit outside the scheme. Exempt owners must still maintain their essential safety provisions.
What happens if I don't lodge a Form 3?
Councils cite $750 expiations for not lodging or not maintaining essential safety provisions, and penalties of up to $10,000 if prosecuted. A Building Fire Safety Committee can also issue a section 157 notice that requires you to act.
What is the difference between Form 1, Form 2 and Form 3?
Form 1 is the schedule of essential safety provisions issued by council or the relevant authority. Form 2 is the installer's certificate, provided on completion of the installation of each provision. Form 3 is the owner's annual maintenance certificate. See our Form 2 page for how the installer's certificate works.
Do you submit the Form 3 for me?
No. Form 3 is the owner's certificate and the owner lodges it. We give you the maintenance records behind it and sign the contractor section for the work we did, so you have what you need to complete and lodge it.
I have more than one Form 1 for my building. What should I do?
Older buildings that have been altered over the years can end up with several schedules. Some councils, such as the City of Marion, say owners may apply to consolidate them into one document. Ask your council how it handles this. We can help by listing what is actually installed on site.

Related guides

Get a quote for essential safety provisions (form 3)

We send quotes the same day and call back within 15 minutes during business hours. Prefer to talk? Call 08 8151 1040.

No obligation. We only use your details to reply to this request.

Book your next service

Tell us what's on site and we'll send a fixed price the same day.

Call 08 8151 1040 Get a quote