Based in Enfield. Working across Adelaide and regional SA. 08 8151 1040

NCC building classes explained for South Australian owners

The National Construction Code sorts every building into Classes 1 to 10 by what it is used for. Class 1 is houses, Class 2 is apartments, Classes 3 to 9 cover other residential, commercial, industrial and public buildings, and Class 10 is sheds, fences and other non-habitable structures. In South Australia the class also decides your Form 3 duty: Class 1a and 10 sit outside the essential safety provisions scheme, small buildings in some classes are exempt from lodging, and Class 2, 9a and 9c buildings have no size exemption.

Building classes come up when you buy a property, change how it’s used, or get a letter from council about Form 3. The class is a number from 1 to 10 that the National Construction Code (NCC) gives every building based on what it is designed for. In South Australia it also tells you whether your building’s fire safety systems sit in the essential safety provisions scheme, and whether you lodge a Form 3 each year.

What are the NCC building classes?

The definitions below come from Part A6 of the NCC 2022 (ABCB) and the ABCB’s building classifications guide.

Class What it is Examples
1a A single dwelling A detached house, or attached townhouses, terraces and villa units separated by fire-resisting walls
1b Small boarding houses, guest houses and hostels of 300 m² or less that ordinarily hold no more than 12 people, or 4 or more single dwellings on one allotment used for short-term holiday accommodation A small guest house or B&B, a group of holiday cabins on one block
2 A building with two or more sole-occupancy units, each a separate dwelling Apartment and unit buildings where people live above and below each other
3 Residential accommodation for unrelated people, long term or short term Larger boarding houses, hostels and backpackers, the residential part of a hotel, motel or school, staff accommodation in a health-care building, some accommodation for the aged, children or people with disability
4 The only dwelling in a Class 5 to 9 building A caretaker’s flat above a shop or in a factory
5 Offices for professional or commercial purposes Lawyers’, accountants’ and government offices
6 Shops and buildings that supply services to the public Shops, cafés, restaurants, hairdressers, supermarkets, showrooms, service stations
7a Carparks A multi-level carpark
7b Storage and wholesale display Warehouses and storage buildings
8 Laboratories and buildings where goods are made, repaired, packed or processed Factories, workshops, food manufacturers, farm packing sheds
9a Health-care buildings Hospitals, including laboratories inside them
9b Assembly buildings Theatres, halls, schools, early childhood centres, sports centres, nightclubs, transport stations
9c Residential care buildings Residential aged care where residents have various care needs
10a Non-habitable buildings Sheds, carports, private garages
10b Non-habitable structures Fences, masts, antennas, retaining walls, swimming pools
10c Private bushfire shelters A shelter associated with, but not attached to, a Class 1a house

The NCC notes that building height doesn’t change a Class 1 classification. A Class 1 dwelling can’t sit above or below another dwelling or another class of building, other than a private garage.

What is a Class 2 building?

A Class 2 building contains two or more sole-occupancy units, and each unit is a separate dwelling. In plain terms, it’s an apartment or unit block. Two points catch owners out:

  • Units over shared space are Class 2. The NCC says single-storey attached dwellings with common space below them, such as a shared car park, are Class 2, not Class 1.
  • Two flats over a shop make a Class 2 part. Only one dwelling in a non-residential building can be Class 4. Add a second and the dwellings are Class 2.

In SA, Class 2 buildings with a schedule of essential safety provisions lodge a Form 3 every year, whatever their size. Smoke alarm rules under regulation 95 also apply to every dwelling in Class 1 and Class 2 buildings. If your building is strata or community titled, our strata fire safety page covers what that means for corporations and managers.

Can a building have more than one class?

Yes. A building, or part of one, can be designed for more than one purpose and carry more than one classification. A shop with apartments above is Class 6 and Class 2. Each part has to meet the requirements for its own class, and where the requirements conflict, the stricter one applies.

There is one shortcut. Under NCC 2022 clause A6G1, a part that takes up less than 10% of a storey’s floor area can take the classification of the rest of that storey. That doesn’t apply to laboratories, to Class 2, 3 or 4 sole-occupancy units, or to early childhood centres.

Which building classes need a Form 3 in SA?

In South Australia, regulation 94 of the Planning, Development and Infrastructure (General) Regulations 2017 sets out the essential safety provisions scheme. Where a building has a schedule of provisions (the Form 1), the owner must have them maintained and tested each calendar year and give council a Form 3 within 60 business days after the end of the year. The class decides how that applies:

Class Essential safety provisions Form 3 each year
1a and 10 Outside the scheme. Regulation 94 does not apply No
1b Must be maintained Exempt from lodging
2, 9a and 9c Must be maintained Yes, at any size
3, 4, 5, 6, 7, 8 and 9b Must be maintained Yes, unless the building has a rise in storeys of 2 or less and a floor area of 500 m² or less

The small-building exemption has limits. Council can still require a Form 3 if the provisions were installed as part of a performance solution, or under a condition that varies from the NCC’s performance requirements, or if the building has been the subject of a notice under section 157 of the Planning, Development and Infrastructure Act 2016. Those notices come from the fire safety bodies councils set up under section 157, usually called Building Fire Safety Committees.

Being exempt from lodging doesn’t mean being exempt from maintaining. Regulation 94 still requires the provisions to be maintained and tested every year, and an authorised officer can ask you for written proof covering up to the two previous calendar years.

“Rise in storeys” has its own definition in the NCC, so it isn’t always the same as the number of floors you’d count from the street. If your building is close to the limits, ask your certifier or council how it is counted.

How do I find my building’s class?

Start with the paperwork. Your development approval documents should state the classification, and the Form 1 lists the essential safety provisions that go with it. If you don’t have either, ask your council for copies. For mixed buildings, ask council how the Form 3 exemption applies to your building, because the answer can depend on which classes are present.

If the building’s use has changed since it was approved, for example a warehouse turned into offices, check that the classification and the Form 1 were updated. Regulation 94 has council issue a new schedule when a classification changes, and an out of date Form 1 can leave you maintaining the wrong list of systems.

Keeping your provisions maintained

Once you know your class, the job is the same for every building in the scheme: service each provision on the Form 1 at the frequency MBS 002 sets, keep the records, and fix defects as they come up. See our essential safety provisions and Form 3 service for how the year works. VD Fire & Electrical maintains essential safety provisions across Adelaide and signs the contractor section of Form 3 for the provisions we look after, and the first fire safety inspection is a free audit. For the day to day side, our annual fire safety checklist lists what is due when.

Frequently asked questions

Is a townhouse Class 1 or Class 2?
Usually Class 1a. The NCC treats attached dwellings such as row houses, terraces, townhouses and villa units as Class 1a when each one is separated by a fire-resisting wall. If one dwelling sits above another, or above shared space such as a common car park, the building becomes Class 2 or Class 3 instead ([NCC 2022 Part A6](https://ncc.abcb.gov.au/editions/ncc-2022/adopted/volume-one/a-governing-requirements/part-a6-building-classification)).
What class is a shop with a flat above it?
The shop is Class 6. If the flat is the only dwelling in the building, the NCC calls it a Class 4 part. A building can have only one Class 4 dwelling, so two or more flats above a shop are Class 2.
What class is an aged care home?
A residential care building is Class 9c, a building where residents may have various care needs. Class 3 also covers some accommodation for the aged, children and people with disability. Your certifier decides which one applies. In SA, Class 9c buildings have no small-building exemption from Form 3.
Who decides a building's class?
The class is set by the purpose the building is designed for, and the ABCB says that where it is unclear, the approval authority has the discretion to decide. If a building's use changes, its classification can change too, which in SA can mean a new schedule of essential safety provisions.
What is the fine for not lodging a Form 3 in SA?
Regulation 94 of the Planning, Development and Infrastructure (General) Regulations 2017 sets an expiation fee of $750 and a maximum penalty of $10,000 for failing to maintain the provisions or lodge the yearly verification.

Book your next service

Tell us what's on site and we'll send a fixed price the same day.

Call 08 8151 1040 Get a quote