Based in Enfield. Working across Adelaide and regional SA. 08 8151 1040

Evacuation diagrams in Adelaide

We draw site-specific evacuation diagrams that show people where they are, the way out and where to assemble, as part of the emergency plan every South Australian workplace must have under WHS regulation 43. A diagram should be updated whenever your layout, exits or fire equipment change, and we quote per site.

What an evacuation diagram is

An evacuation diagram is a simplified floor plan, mounted on the wall, that shows a reader three things fast: where they are now, the nearest way out, and where to go once they are outside. It also marks the fire equipment nearby, so a warden or staff member can find an extinguisher, hose reel or alarm call point without searching.

A diagram is not the whole emergency plan. The plan is the written set of procedures for your workplace. The diagram is the part people can read in a few seconds while an alarm is sounding. That is why each one is drawn for the exact spot it hangs in, not copied from a single master plan.

What South Australian law requires

Every person conducting a business or undertaking must have an emergency plan for the workplace under regulation 43 of the Work Health and Safety Regulations 2012 (SA). The plan must cover emergency procedures, including an effective response, evacuation, notifying emergency services early, medical treatment and communication with the person coordinating the response. It must also cover how often those procedures are tested, and the information, training and instruction relevant workers get. The plan has to be kept effective and put into action if an emergency happens.

When you prepare the plan, the regulation asks you to consider the nature of the work, the hazards, the size and location of the workplace, and the number and mix of people there. A two-person office and a three-storey aged care home need very different plans.

AS 3745, the Australian Standard for planning for emergencies in facilities, is the recognised best practice for how plans and diagrams are put together. We have found no South Australian law that makes it mandatory for every workplace, so we will not tell you it is. Many clients still ask for AS 3745-style diagrams because insurers, head offices or contracts expect them, and because the format works.

Some settings have their own rules on top:

  • Childcare centres must rehearse their emergency and evacuation procedures every 3 months, according to ACECQA.
  • New SDA dwellings must give the occupier an evacuation plan under the SDA Design Standard, edition 1.1.
  • NDIS providers must have emergency plans that are tested and reviewed, with every worker trained, under the NDIS Practice Standards.
  • Aged care providers must have emergency plans that are regularly tested under outcome 2.10 of the strengthened Aged Care Quality Standards.

What our diagrams show

Every diagram we draw is checked on site. It marks a “You are here” point, the exits and routes from that spot, the assembly area and the fire equipment nearby, and it is turned to match the way the reader faces.

Sample A4 evacuation diagram by VD Fire and Electrical: a ground floor plan with a You are here marker, green exit routes, exit signs, extinguishers, fire blankets and the assembly area, beside a site plan, evacuation procedures, the RACE fire steps and a legend
A sample diagram we drew for a regional hotel, with the client's details removed. Each sign carries its own floor plan, site plan, procedures and legend. Open the full size sample.

How we produce them

  1. You send floor plans if you have them. Architectural plans, a fire services layout or even a clear sketch helps. If there are none, we measure up on the day.
  2. We walk the site. Our technician checks every exit and route, notes where equipment actually is, and marks the best wall positions for each diagram.
  3. We draft the diagrams. Each one is drawn for its own position, so a building with four floors and two stairwells may need several versions.
  4. You check a proof. You confirm the assembly area and any site-specific details before anything is printed.
  5. We deliver. You receive the finished diagrams. Ask us about printing and mounting when you order.

When to update a diagram

An out-of-date diagram can send people towards a door that is now locked or an extinguisher that has moved. Update your diagrams when:

  • You renovate, add or remove walls, or change the fit-out
  • An exit is added, closed or changed
  • Fire equipment is added or moved
  • Your assembly area changes
  • You take over a new tenancy or building

Because we also service extinguishers, hose reels and exit lights, we notice when equipment positions no longer match the diagram and tell you during the regular service visit.

Diagrams for SDA, aged care and childcare

Homes and care settings need more thought than an office. In an SDA home, the diagram should match the resident’s own evacuation plan and be easy for the resident and support workers to follow. In aged care, where many residents need help to leave, diagrams work alongside staff procedures and drills. In childcare, diagrams support the 3-monthly rehearsals so every educator knows the route and the assembly point.

Shared buildings and multi-site clients

In a building with several tenants, the building owner and each tenant all have parts to play. The owner usually controls the common areas, exits and fire systems, while each tenant has its own staff, visitors and emergency plan. We can draw diagrams for the common areas and for each tenancy so that the routes and assembly area match across the whole building, rather than every tenant drawing their own version.

For property managers, SDA providers and businesses with several sites, we can keep each site’s drawings on file. When a layout changes, we update the drawing instead of starting again, and every site’s diagrams can follow the same format, so staff who move between sites see a familiar layout.

What to have ready

A quick quote needs your site address, the number of floors or buildings, and any floor plans you hold. If you already have an emergency plan, send it too, so the diagrams match the procedures and assembly area already in it.

Standards and service frequency in SA

EquipmentHow oftenStandardSA source
Workplace emergency plan Prepared, kept effective and acted on in an emergency. The plan sets how often procedures are tested WHS Regulations 2012 (SA), regulation 43 SafeWork SA
Evacuation diagrams Review whenever layout, exits or equipment change AS 3745-2010 (best practice, but no SA law found mandates it) SafeWork SA
Childcare evacuation rehearsals Every 3 months Education and Care Services National Regulations ACECQA
New SDA dwellings Evacuation plan given to the occupier SDA Design Standard, edition 1.1 (new SDA from 1 July 2021) NDIS

Who this is for

Certificates and reporting

Every visit ends with a written report listing each item tested, its location and result, and anything that needs attention. Building owners use it as the maintenance record behind their annual Form 3. We are qualified and authorised to carry out fire safety maintenance and sign off SA council ESP Form 2 and Form 3 maintenance documentation.

Ask us for a sample report if you want to see the format before you book.

Who does the work

  • FPAS Recognised BusinessFire Protection Accreditation Scheme
  • FPA Australia Bronze MemberFire Protection Association Australia
  • Engineers AustraliaMember of the national body for engineers
  • CBS PGE fire plumbing licenceConsumer and Business Services SA
  • Licensed for electrical test and tagAS/NZS 3760 testing

All licences and certificates are held by suitably qualified personnel, and we are fully insured.

Frequently asked questions

Are evacuation diagrams a legal requirement in South Australia?
Every workplace must have an emergency plan under WHS regulation 43, and that plan must cover evacuation procedures. We found no SA law that names AS 3745 or mandates a particular diagram format. In practice, a clear diagram on the wall is one of the simplest ways to show workers and visitors how your evacuation procedure works.
What is the difference between an evacuation diagram and an evacuation plan?
The evacuation plan, or emergency plan, is the written document: who does what, how people get out, who calls emergency services and how the procedures are tested. The diagram is the picture of that plan for one spot in the building. You need the plan. The diagram helps people follow it.
Do I have to follow AS 3745?
AS 3745 is the Australian Standard for planning for emergencies in facilities and is widely used as best practice. No SA law we have found mandates it for every workplace. Some clients, insurers and contracts ask for it, so we lay out our diagrams with it in mind.
How often should evacuation diagrams be reviewed?
Whenever something on the diagram changes: a new wall, a blocked exit, a moved extinguisher or a new assembly area. Check them whenever you review your emergency plan too.
Where should evacuation diagrams be placed?
Where people will see them on the way out: near exits, lifts, stairwells, reception and the main corridors of each floor. Each diagram is drawn for the spot it hangs in, so the "You are here" point and the map's orientation match what the reader sees.
Do SDA homes need an evacuation plan?
Yes. The SDA Design Standard (edition 1.1, for new SDA from 1 July 2021) requires an evacuation plan to be given to the occupier. We can draw a simple diagram for the dwelling that matches the resident's own plan.
How much do evacuation diagrams cost?
We quote per site, based on floor area, the number of diagrams and whether you want them printed and mounted. Send us your floor plans for a faster quote.

Related guides

Get a quote for evacuation diagrams

We send quotes the same day and call back within 15 minutes during business hours. Prefer to talk? Call 08 8151 1040.

No obligation. We only use your details to reply to this request.

Book your next service

Tell us what's on site and we'll send a fixed price the same day.

Call 08 8151 1040 Get a quote