Based in Enfield. Working across Adelaide and regional SA. 08 8151 1040

Emergency management and evacuation plans in Adelaide

We draft and design emergency and evacuation plans for Adelaide workplaces, meeting the duty every South Australian workplace has under WHS regulation 43 and covering evacuation, alerting emergency services, roles and testing. A plan should be reviewed whenever your site, people or procedures change, and we quote per site.

What an emergency plan is

An emergency plan is the written set of procedures your workplace follows when something goes wrong: a fire, a gas leak, a medical emergency, a bomb threat, a storm or an intruder. It says who raises the alarm, how people get out or shelter in place, who calls 000, who looks after people who need help, and how everyone is accounted for.

It is not a document for the shelf. A good plan is short enough for wardens to know by heart, specific to your building, and tested often enough that people follow it without thinking.

What South Australian law requires

Every person conducting a business or undertaking must have an emergency plan for the workplace under regulation 43 of the Work Health and Safety Regulations 2012 (SA). The plan must provide for:

  • emergency procedures, including an effective response to an emergency
  • evacuation procedures
  • notifying emergency services at the earliest opportunity
  • medical treatment and assistance
  • effective communication between the person authorised to coordinate the response and everyone at the workplace
  • testing of the emergency procedures, including how often they are tested
  • information, training and instruction for relevant workers on carrying out the procedures

The plan has to be maintained so it stays effective, and put into action if an emergency happens. When preparing it, you must consider the nature of the work, the hazards, the size and location of the workplace, and the number and make-up of the people there.

SafeWork SA’s Code of Practice on managing the work environment and facilities explains these requirements and points to AS 3745 for further guidance.

Where AS 3745 fits

AS 3745, Planning for emergencies in facilities, is the Australian Standard for emergency planning. It describes an emergency planning committee, an emergency control organisation of wardens, emergency procedures, evacuation diagrams and exercises. It is widely used as best practice.

We have found no South Australian law that makes AS 3745 mandatory for every workplace, so we won’t tell you it is. Many clients still want a plan that follows its structure, because insurers, head offices and contracts expect it, and because the structure works. See our guide to AS 3745.

What our plans cover

Each plan covers everything regulation 43 lists above, written for your building, your people and your hazards. Tell us what else your insurer, head office or contract expects and we’ll build it in.

Plans and diagrams together

A plan and its evacuation diagrams should match exactly: the same exits, routes and assembly area. We draw both from the same site walk, so a change to one is made in the other. Because we also service extinguishers, exit lights and alarms, we notice when the building no longer matches the plan.

Training wardens and testing the plan

A plan only works if people know it. Wardens need to know their area, their role and the plan’s procedures, and everyone else needs to know the alarm and the route. Regulation 43 requires the plan to cover training and how often the procedures are tested. We write those parts into the plan, so it is clear who is trained, in what, and when the next drill is due. See our guide to fire drills.

After each drill, write down what happened: the date, the scenario, how long it took, who took part, what went wrong and what will change. Those records show that the plan has been tested and kept effective.

Sector rules on top of the WHS duty

  • Childcare services must rehearse their emergency and evacuation procedures every 3 months. South Australia’s Education Standards Board expects one evacuation and one invacuation rehearsal every 3 months, and the potential emergencies risk assessment reviewed every 12 months.
  • Aged care providers must have emergency plans that are regularly tested under outcome 2.10 of the strengthened Aged Care Quality Standards.
  • NDIS providers must have emergency plans that are tested and reviewed, with every worker trained, under the NDIS Practice Standards.
  • New SDA dwellings must give the occupier an evacuation plan under the SDA Design Standard, edition 1.1.

What to have ready

Send us your site address, floor plans if you have them, your current plan if there is one, the number of people on site at the busiest time, and anyone who would need help to evacuate. We use those to scope the plan and quote.

Standards and service frequency in SA

EquipmentHow oftenStandardSA source
Workplace emergency plan Prepared, maintained so it stays effective, and put into action in an emergency. The plan sets how often procedures are tested WHS Regulations 2012 (SA), regulation 43 SafeWork SA
Emergency planning in facilities Used as a guide to how the plan is set out AS 3745-2010 (best practice, but no SA law found mandates it) SafeWork SA Code of Practice
Childcare emergency and evacuation rehearsals Every 3 months Education and Care Services National Regulations ACECQA and Education Standards Board SA
NDIS providers Emergency plans tested and reviewed, with every worker trained NDIS Practice Standards NDIS Commission
Aged care providers Emergency plans regularly tested Strengthened Aged Care Quality Standards, outcome 2.10 ACQSC

Who this is for

Certificates and reporting

Every visit ends with a written report listing each item tested, its location and result, and anything that needs attention. Building owners use it as the maintenance record behind their annual Form 3. We are qualified and authorised to carry out fire safety maintenance and sign off SA council ESP Form 2 and Form 3 maintenance documentation.

Ask us for a sample report if you want to see the format before you book.

Who does the work

  • FPAS Recognised BusinessFire Protection Accreditation Scheme
  • FPA Australia Bronze MemberFire Protection Association Australia
  • Engineers AustraliaMember of the national body for engineers
  • CBS PGE fire plumbing licenceConsumer and Business Services SA
  • Licensed for electrical test and tagAS/NZS 3760 testing

All licences and certificates are held by suitably qualified personnel, and we are fully insured.

Frequently asked questions

Does every workplace in South Australia need an emergency plan?
Yes. Regulation 43 of the Work Health and Safety Regulations 2012 (SA) requires the person conducting a business or undertaking to have an emergency plan for the workplace. A small office needs one as much as a factory. The plan just needs to suit the size, hazards and people of the site.
What must an emergency plan include?
Emergency procedures, including an effective response, evacuation, notifying emergency services at the earliest opportunity, medical treatment and assistance, and communication between the person coordinating the response and everyone at the workplace. It must also cover how often the procedures are tested, and the information, training and instruction given to relevant workers.
Is AS 3745 mandatory in South Australia?
We have found no SA law that mandates AS 3745. It is the Australian Standard for planning for emergencies in facilities and is widely used as best practice, and SafeWork SA's code of practice points to it. Some insurers, head offices and contracts ask for it, so we lay out plans with it in mind.
What is the difference between an emergency plan and an evacuation diagram?
The emergency plan is the written document: what to do, who does it, how people are alerted and how the plan is tested. An evacuation diagram is a picture of the evacuation part of that plan, mounted on the wall for one spot in the building. You need the plan. The diagrams help people follow it. See our evacuation diagrams page.
How often should an emergency plan be tested?
The law leaves the frequency to the plan itself: regulation 43 says the plan must include testing of the procedures, including how often. Some sectors set a minimum. Childcare services must rehearse their emergency and evacuation procedures every 3 months. Aged care and NDIS providers must test their plans regularly.
How often should an emergency plan be reviewed?
Whenever something it relies on changes: the layout, exits, alarm system, tenants, number of people, people who need help to evacuate, or the wardens. Review it after every drill and every real incident too.
Do you write plans for shared or multi-tenant buildings?
Ask us. In a shared building, the owner's plan for the common areas and alarm system and each tenant's own plan need to agree on the alarm signal, the routes, the assembly area and who acts as chief warden.

Related guides

Get a quote for emergency management plans

We send quotes the same day and call back within 15 minutes during business hours. Prefer to talk? Call 08 8151 1040.

No obligation. We only use your details to reply to this request.

Book your next service

Tell us what's on site and we'll send a fixed price the same day.

Call 08 8151 1040 Get a quote