What an emergency plan is
An emergency plan is the written set of procedures your workplace follows when something goes wrong: a fire, a gas leak, a medical emergency, a bomb threat, a storm or an intruder. It says who raises the alarm, how people get out or shelter in place, who calls 000, who looks after people who need help, and how everyone is accounted for.
It is not a document for the shelf. A good plan is short enough for wardens to know by heart, specific to your building, and tested often enough that people follow it without thinking.
What South Australian law requires
Every person conducting a business or undertaking must have an emergency plan for the workplace under regulation 43 of the Work Health and Safety Regulations 2012 (SA). The plan must provide for:
- emergency procedures, including an effective response to an emergency
- evacuation procedures
- notifying emergency services at the earliest opportunity
- medical treatment and assistance
- effective communication between the person authorised to coordinate the response and everyone at the workplace
- testing of the emergency procedures, including how often they are tested
- information, training and instruction for relevant workers on carrying out the procedures
The plan has to be maintained so it stays effective, and put into action if an emergency happens. When preparing it, you must consider the nature of the work, the hazards, the size and location of the workplace, and the number and make-up of the people there.
SafeWork SA’s Code of Practice on managing the work environment and facilities explains these requirements and points to AS 3745 for further guidance.
Where AS 3745 fits
AS 3745, Planning for emergencies in facilities, is the Australian Standard for emergency planning. It describes an emergency planning committee, an emergency control organisation of wardens, emergency procedures, evacuation diagrams and exercises. It is widely used as best practice.
We have found no South Australian law that makes AS 3745 mandatory for every workplace, so we won’t tell you it is. Many clients still want a plan that follows its structure, because insurers, head offices and contracts expect it, and because the structure works. See our guide to AS 3745.
What our plans cover
Each plan covers everything regulation 43 lists above, written for your building, your people and your hazards. Tell us what else your insurer, head office or contract expects and we’ll build it in.
Plans and diagrams together
A plan and its evacuation diagrams should match exactly: the same exits, routes and assembly area. We draw both from the same site walk, so a change to one is made in the other. Because we also service extinguishers, exit lights and alarms, we notice when the building no longer matches the plan.
Training wardens and testing the plan
A plan only works if people know it. Wardens need to know their area, their role and the plan’s procedures, and everyone else needs to know the alarm and the route. Regulation 43 requires the plan to cover training and how often the procedures are tested. We write those parts into the plan, so it is clear who is trained, in what, and when the next drill is due. See our guide to fire drills.
After each drill, write down what happened: the date, the scenario, how long it took, who took part, what went wrong and what will change. Those records show that the plan has been tested and kept effective.
Sector rules on top of the WHS duty
- Childcare services must rehearse their emergency and evacuation procedures every 3 months. South Australia’s Education Standards Board expects one evacuation and one invacuation rehearsal every 3 months, and the potential emergencies risk assessment reviewed every 12 months.
- Aged care providers must have emergency plans that are regularly tested under outcome 2.10 of the strengthened Aged Care Quality Standards.
- NDIS providers must have emergency plans that are tested and reviewed, with every worker trained, under the NDIS Practice Standards.
- New SDA dwellings must give the occupier an evacuation plan under the SDA Design Standard, edition 1.1.
What to have ready
Send us your site address, floor plans if you have them, your current plan if there is one, the number of people on site at the busiest time, and anyone who would need help to evacuate. We use those to scope the plan and quote.
Standards and service frequency in SA
| Equipment | How often | Standard | SA source |
|---|---|---|---|
| Workplace emergency plan | Prepared, maintained so it stays effective, and put into action in an emergency. The plan sets how often procedures are tested | WHS Regulations 2012 (SA), regulation 43 | SafeWork SA |
| Emergency planning in facilities | Used as a guide to how the plan is set out | AS 3745-2010 (best practice, but no SA law found mandates it) | SafeWork SA Code of Practice |
| Childcare emergency and evacuation rehearsals | Every 3 months | Education and Care Services National Regulations | ACECQA and Education Standards Board SA |
| NDIS providers | Emergency plans tested and reviewed, with every worker trained | NDIS Practice Standards | NDIS Commission |
| Aged care providers | Emergency plans regularly tested | Strengthened Aged Care Quality Standards, outcome 2.10 | ACQSC |
Who this is for
- Commercial officesWe service the fire safety systems in Adelaide offices and commercial buildings, from extinguishers and exit lights to alarms and fire doors, and supply the records behind the owner's Form 3.
- Industrial and warehousesWe service the fire safety systems in Adelaide warehouses, factories and industrial sites, from extinguishers and hose reels to hydrants, sprinklers and exit lights, and test and tag the equipment on the floor.
- Aged careWe install and maintain the fire safety systems in Adelaide's Class 9c aged care homes, from sprinklers and monitored smoke detection to exit lighting, fire doors and extinguishers, and supply the records behind your Form 3.
- SDA and NDIS homesWe set up and maintain the fire safety in Specialist Disability Accommodation (SDA) and supported independent living (SIL) homes across Adelaide, from fire risk assessments and the move-in package to 6-monthly servicing and audit-ready records.
- Schools and childcareWe service the fire safety equipment in Adelaide schools, kindergartens and childcare centres, and help services prepare for the evacuation rehearsals they must run.
- Healthcare and medicalWe service the fire safety systems in Adelaide medical centres, dental and allied health clinics and other healthcare buildings, and supply the records behind the owner's Form 3.
- Construction sitesWe test and tag site electrical equipment, supply and service fire extinguishers, and help builders put emergency plans in place on Adelaide construction sites.
- Hospitality and retailWe service the fire safety equipment in Adelaide restaurants, cafés, pubs and shops, from wet chemical extinguishers and fire blankets in the kitchen to exit lights and test and tag.
Certificates and reporting
Every visit ends with a written report listing each item tested, its location and result, and anything that needs attention. Building owners use it as the maintenance record behind their annual Form 3. We are qualified and authorised to carry out fire safety maintenance and sign off SA council ESP Form 2 and Form 3 maintenance documentation.
Ask us for a sample report if you want to see the format before you book.
Who does the work
- FPAS Recognised BusinessFire Protection Accreditation Scheme
- FPA Australia Bronze MemberFire Protection Association Australia
- Engineers AustraliaMember of the national body for engineers
- CBS PGE fire plumbing licenceConsumer and Business Services SA
- Licensed for electrical test and tagAS/NZS 3760 testing
All licences and certificates are held by suitably qualified personnel, and we are fully insured.