Every workplace in South Australia needs an emergency plan, and evacuation is the core of it. Regulation 43 of the WHS Regulations sets out what the plan must cover, and SafeWork SA’s guidance explains how to write one that works on the day.
What does SA law require?
Regulation 43 of the Work Health and Safety Regulations 2012 (SA) says a person conducting a business or undertaking must make sure an emergency plan is prepared for the workplace that provides for:
- Emergency procedures, including an effective response to an emergency, evacuation procedures, notifying emergency services at the earliest opportunity, medical treatment and assistance, and effective communication between the person coordinating the response and everyone at the workplace.
- Testing of the emergency procedures, including how often they are tested.
- Information, training and instruction for relevant workers on carrying out the procedures.
You must also maintain the plan so it stays effective, and put it into action in an emergency. Each of those three duties carries a maximum penalty of $6,000 for an individual and $30,000 for a body corporate.
SafeWork SA’s emergency response guidance adds that the plan should be written, displayed prominently, easy to understand and specific to the site.
What should an emergency evacuation plan include?
SafeWork SA’s Code of Practice: Managing the work environment and facilities lists what the procedures should address where relevant. Use it as your checklist:
- who does what in an emergency, such as appointed area wardens
- how the alarm is raised and how people are alerted
- clear lines of communication between whoever coordinates the response and everyone on site
- the safety of everyone who may be there, including visitors, shift workers and tradespeople
- people who will need help to evacuate
- procedures for critical functions, such as shutting off power
- safe places and assembly points
- risks from neighbouring businesses, and possible traffic restrictions
- a site plan showing fire protection equipment, exits and assembly points
- emergency phone numbers, including after-hours contacts
- access for emergency services
- regular evacuation practice drills at least every 12 months
- the use and maintenance of emergency equipment, such as extinguishers, smoke detectors and sprinklers
- regular review of the procedures and training
A more detailed plan may be needed where people sleep on site, where large crowds gather, where there are high-risk chemical processes, or where significant cash is handled.
What do you need to consider when writing the plan?
Regulation 43 says you must consider the nature of the work, the hazards, the size and location of the workplace, and the number and make-up of the people there. SafeWork SA adds shared workplaces, how remote the site is and how close it is to health services, and workers who travel, work alone or work remotely.
The code also asks you to look outside your fence. Its example is a chemical storage facility across the road. A cafe beside a warehouse, or a business on the urban fringe in bushfire season, faces risks that start next door.
Who prepares the plan in a shared building?
In a workplace shared by several businesses, such as a shopping centre or a multi-tenant office, the code says the plan should be coordinated by the person with management or control of the workplace. That may be the property manager, principal contractor or landlord, working with all the tenants. When a new business moves in, the existing plan should be reviewed for any new types of emergency it brings.
You must consult workers and their health and safety representatives when you review the plan. If an emergency at your workplace could have significant consequences, the code says to consult the local emergency services as well.
How often should you test and review the plan?
The plan itself must say how often the procedures are tested. The code’s list includes evacuation practice drills at least every 12 months, and some sectors set a shorter interval. See our guide to fire drills for how to run one.
SafeWork SA says to review and revise the plan when:
- the workplace changes, such as a move or refurbishment
- staffing changes, including more temporary workers or contractors
- new work activities start
- a test shows something that needs fixing
Workers should take part in tests and give feedback.
Where do evacuation diagrams fit?
The code says evacuation procedures should be displayed in a prominent place, such as a noticeboard, and that the procedures should address the display of a site plan showing fire protection equipment, emergency exits and assembly points. An evacuation diagram on the wall is the usual way to do that.
AS 3745 sets out what a good diagram contains. No SA law we have found requires diagrams drawn to AS 3745. See our guide to evacuation diagram requirements in SA and our evacuation diagrams service.
Is AS 3745 required in South Australia?
AS 3745, Planning for emergencies in facilities, is the Australian Standard for emergency plans, warden organisations, diagrams and exercises. SafeWork SA’s code points to AS 3745-2010 for further guidance on emergency plans and procedures. It is widely used as best practice, and a lease, insurer or head office may ask for it, but we have found no SA law that makes it mandatory. See our guide to AS 3745.
Training the people who run the plan
A plan works only if people know it. SafeWork SA says training can cover evacuation drills, assembly points, emergency equipment, first aid and safe shutdown of machinery. Include it in inductions, give refresher training, and give specific training to fire or floor wardens and first aid officers. See our guide to fire warden roles and hat colours.
VD Fire & Electrical drafts emergency management plans, draws diagrams and trains wardens for workplaces across Adelaide, from Mawson Lakes to Port Adelaide. Plans are quoted per site, and your first fire safety audit is free. Call 08 8151 1040.